Conditional grantDecided 29 November 2024Carlow County Council

2360318: A new single-storey detached laboratory and office (43sqm) and for lower tier CoMAH status on its Clorusk Lower Site. All at Royal Oak Distillery. Clorusk Lower, Royal Oak, Bagenalstown, Co. Carlow. Holloden Royal Oak is a protected structure, RPS ref. CW46 (NIAH No.10301620)

Clorusk Lower, Royal Oak, Bagenalstown
DecisionConditional grant
Decided29 November 2024
Application typePERMISSION
Source documents8

Site

What is on file

0refusal reasons16conditions8nearby records

Decision details

Core application dates and identifiers from the public planning record.

Planning analysis

Refusal reasons and planning conditions extracted from the public decision file.

Refusal reasons

No refusal reason

No refusal reason is on record for this application yet.

Conditions

  • , Development must follow approved plans received 22/12/2023, amended by FI on 17/09/2024 and clarification on 15/11/2024.Compliance
  • , External finishes per elevation drawing PL-003 received 17/09/2024.Design Materials
  • , NIS mitigation strictly implemented. Prevent spread of Alien Invasive Species. Comply with CIRIA C532. Supervision by qualified ecological clerk of works.Environment Ecology
  • , Final CEMP submitted for written agreement prior to commencement, covering programme, monitoring, emergency plan, weekly meetings, and public liaison.Construction Management
  • , Adhere to Discharge Licence D1/S16/2013/17. Enter Connection Agreement with Uisce Éireann if connected to public water. Comply with Uisce Éireann Standard Details.Water Services
  • , No advertising signage or structures without prior written agreement.Other
  • , Surface water disposed on site via soakaways per BS 8301:1985 and BRE Digest 365. Foul sewage to public foul sewer. Clean surface water to surface water system.Wastewater Drainage
  • , Do not interfere with public road/footpath without Municipal District Engineer agreement. Road Opening License required for openings.Traffic Access
  • , Firewater drainage system per approved drawings, hydrocarbon interceptors, fire basin, retention system min 2090m3, concrete tank min 1000m3, lined basin min 1090m3 with HDPE liner.Compliance
  • , External lighting low energy, directed to prevent nuisance to neighbours and road users.Other
  • , Noise/vibration per BS 5228-1:2009+A1:2014 and BS 5228-2+A1:2014. Dust < 350mm/m²/day per VDI 2119.Other
  • , Best Practicable Means for noise/dust. Off carriageway parking. Site neat/litter free. Prevent muck on public road. Removed material to licenced facilities.Construction Management

Source documents

Original council portal records and source PDFs where available.

Nearby precedent

Similar nearby applications linked to this planning decision.