Conditional grantDecided 24 October 2025Carlow County Council

2460424: The construction of a single storey dwelling, domestic garage, bored well, secondary treatment system & soil polishing filter, and all associated site works

Clogrennan, Ballinabranagh, Co. Carlow
DecisionConditional grant
Decided24 October 2025
Application typeOUTLINE PERMISSION
Source documents6

Site

What is on file

0refusal reasons13conditions8nearby records

Decision details

Core application dates and identifiers from the public planning record.

Planning analysis

Refusal reasons and planning conditions extracted from the public decision file.

Refusal reasons

No refusal reason

No refusal reason is on record for this application yet.

Conditions

  • , Outline permission authorises one dwelling, garage, well, and wastewater system as submitted 20/12/2024 and amended 29/09/2025.Compliance
  • ,No development until a consequent permission application is granted by the Planning Authority.Compliance
  • ,Consequent permission application must be submitted within 3 years of notification.Compliance
  • ,Dwelling max 5.5m height, traditional vernacular architecture. Finishes: natural stone, wet dash, or nap plaster. No brick/reconstituted stone. Roof: blue/black or slate grey tiles/slates only.Design Materials
  • ,All service lines and cables shall be located underground unless otherwise agreed.Other
  • ,Only foul sewage and soiled water shall be discharged to the treatment systems.Wastewater Drainage
  • ,Landscaping and boundary treatments per Landscape Design & Planning Ltd plan (29/09/2025). Trees/hedgerows protected and replaced if failed within 5 years.Landscaping Boundary
  • ,Surface water contained on site, diverted to soakaways per BRE Digest 365. No interference with roadside drainage without Municipal Engineer approval. Road Opening Licence required for public road openings.Wastewater Drainage
  • ,Wastewater system per EPA Code of Practice (June 2021). Certificate of Compliance required before occupation. I.S. EN 12566 testing. Max 6 distribution pipes, liquid levelling device, vent pipes, no surface water infiltration, grease trap.Wastewater Drainage
  • ,Comply with Uisce Éireann connection agreements and CDS Technical Documentation. New/revised agreements required if impact is significant.Water Services
  • ,Consult Chief Fire Officer and strictly comply with recommendations before development commences.Compliance
  • ,Entrance gateway max 1.5m (timber post/rail, nap plaster wall, or stone). Driveway unbound gravel only. Lines of sight per DMRB and site plan. Surface water not discharged to road.Traffic Access